jueves, 26 de agosto de 2021

SCR files as autocad script change to screensaver type

 Files screensavers .scr is associate with autocad script

SOLUTIONS

* open regedit

HKEY_CLASSES_ROOT\.scr

* in Default value data enter: scrfile

* close regedit

THEN

* open cmd with elevate privilege (run as administrator)

type enter: assoc .scr=

type enter: assoc .scr=scrfile

exit cmd


READY


jueves, 7 de junio de 2018

Apuntar clientes Autocad a otro servidor de licencias

Si tu servidor de licencias de Autocad a cambiado y necesitas apuntar a los clientes al nuevo servidor, realiza los siguientes pasos:

- En el equipo del cliente ve a esta ruta C:\ProgramData\Autodesk\CLM\LGS\ 
- Ingresa a la carpeta que te aparezca ahi
- luego abre con notepad el archivo Licpath.lic
- tendrá información similar a esto:

"Server        Servername        000000000000"

- En donde este el hostname del servidor que estas dando de baja, cambialo por el hostname nuevo del servidor.

- Guarda el archivo.
- Verifica abriendo Autocad

Revisar que impresoras tiene asignadas un usuario

Para revisar o verificar de forma remota, que impresoras tiene configurado un usuario, utilizar el siguiente comando de powershell:

To check or verify remotely, which printers a user has configured, use the following powershell command:

Get-WmiObject Win32_Printer -ComputerName PC0001| Select SystemName, Name, Path



(PC0001=HOSTNAME REMOTE PC)


viernes, 2 de marzo de 2018

requirements to Install agent SCCM 2012

Description
UDP
TCP
HTTP from the client computer to a fallback status point
. not applicable
80
Server Message Block (SMB) between the site server and client computer
. not applicable

445
RPC endpoint mapper between the site server and the client computer
135
135
RPC dynamic ports between the site server and the client computer
. not applicable
Dynamic

HTTP from the client computer to an intranet-only management point
. not applicable
80
HTTPS from the client computer to an Internet-capable management point.
Not applicable
443
also Internet Control Message Protocol (ICMP) echo request (PING) messages 

installing Autocad Error 1606

Error 1606 installing Autocad:

In my case, we have a Windows image in which we have configured the path of the user profiles on
disk D: (D: \ User) and the Operating System on disk C:

SOLUTION
- open regedit
- go to:
  • HKEY_LOCAL_MACHINE
  • Software
  • Microsoft
  • Windows
  • CurrentVersion
  • Explorer
  • Shell Folders
  • Replace c:\users\...... for D:\users\... on: desktop, documents, music, pictures, videos, as shown in the picture.

- log off log on 
- try install Autocad again.

Adding network printer and receiving 0x000005b3 error

When trying to add a network printer, the following error occurs:


SOLUTIONS
- Run the Disk Cleanup (Liberador de Espacio en Disco (de Windows))
- Select C:
- Select "Installation log files"
- Delete manually *.tmp from c:\windows\system32
-log off log on
- Try agaim add network print

viernes, 27 de octubre de 2017

Listar drivers instalados en el equipo

para listar los drivers instalados en el equipo, desde el cmd ejecuta el siguiente comando:

pnputil.exe -e